Stratco Colorbond Roofing Prices – Iron has endless appeal to this product. Quality steel roofing, siding and siding are available in long sheet lengths and a wide range of colors.
CGI corrugated has the advantages of strength, adaptability and easy processing and installation. It is a practical and versatile coating solution for roofs, walls and ceilings.
Stratco Colorbond Roofing Prices
CGI is made of high strength steel for strength and impact resistance. It is available in longer lengths for extra durability and better looks. It has a non-siphonable side loop that reduces the risk of moisture transfer between sheets due to capillary action, thus reducing the risk of roof leaks. CGI Corrugatedis is available in a wide range of zinc/al painted and pre-painted colours.
Stratco Cooldek Roofing For Superior Comfort All Year Round
For lengths over 1.2 meters, the CGI shaped sheet will be rolled to the specific length you require, provided satisfactory transport and handling facilities are arranged. If a length of more than ten meters is required, contact your nearest dealer for handling and shipping advice.
To give your roof a professional finish, self-drilling screws are available. CGI offers a full range of accessories and flashes for use with the sheet and can provide professional advice on specific flashes. In addition to straight CGI sheets, there are pre-curved or bullinozed CGI sheets.
The CGI roof has a coverage of 762 mm and a minimum recommended roof pitch of five degrees (1 in 12). CGI roofs are subject to thermal expansion. Dark colors have more impact than light ones, and curved spring leaves require more attention. The maximum length in front of the wide outlet is 24 m for light colors and 16 m for dark colors. For curved spring sheets, this distance is 20 m for light color and 16 m for dark color.
CGI corrugated roofs can be spring curved using purlins spacing 800mm for .42mm BMT and 1000mm for .48mm BMT. The curve should have a radius of 12 m for .42 mm BMT and a radius of 10 m for .48 mm BMT. The maximum radius for suitable drainage on the mountain is 35 m. Side laps must be sealed where the roof height is less than the recommended minimum.
Steel Roofing & Walling Sheets
Custom cut sheets are available allowing you to reduce waste and enhance your design options Corrugated CGI cover is available in an attractive range of zinc/alloy and pre-painted colours. Delivery Depending on location, quantity and availability of materials, delivery is usually within 48 hours or at a time agreed upon according to your construction plan. Unless otherwise recommended, one ton is usually used for the largest package.
Truck unloading arrangements are the customer’s responsibility and must be arranged prior to ordering. When unloading, you should make sure that the load is sufficiently spread and avoid using spreaders and punches. If the bundles are to be loaded directly over structural members, they must be of sufficient strength, such as portal frames or reinforced roof trusses.
Wind capacity tables are based on tests in accordance with AS1562.1-1992 and AS4040.0, 1 and 2-1992. Interval tables are prepared by determining air pressure in accordance with AS4055-2006 for domestic applications and AS/NZS 1170.2:2002 for all other applications. Tables are limited in capacity
Intervals are determined by wind speed for non-cyclonic areas. For domestic applications, arches and spans are based on the maximum: height of six meters, roof height of 35 degrees and total roof height of 8.5 meters. For commercial and industrial applications, tables are based on a maximum height of ten meters and a design return period of 500 years.
Stratco OutbackⓇ Sunroof Vs. Vergola
Roof calculation is based on Cpe=-0.9 and Cpi=0.2, wall installation is based on Cpe=-0.65 and Cpi=0.2. A local stress factor, Kl = 2.0 was used for all roof and wall distances for both strength and serviceability limit conditions. The roof levels allow for random loads to be stored.
All pressures are determined assuming that wind loading in any direction does not affect the topography. The following protection factors are used for each terrain category: category 3 = 0.85, category 2.5 = 0.95 and category 2 = 1.
The size of cars and porches only applies to structures that are not surrounded by perimeter walls. Spans are based on Cpn=-0.9 and Kl=1.5, which apply to all spans and are suitable for all span types. Loads on supporting purlins can limit this span.
For indoor applications, use the appropriate air classification for the area. To read the spacing table for commercial and industrial applications, select the area and area category and then convert to the correct classification using the table below.
Stratco Gable/edge Roll 2.4m Colorbond
Roof areas are limited based on normal pedestrian traffic. Wall size is based on N1 (W28) wind loading. Spacing is based on three fasteners per sheet per support. For use with steel supports with a minimum thickness of 0.75mm standard, G550.
*Note: A roof pitch greater than 20 degrees requires other inspection tools. Therefore, the standard limits the height of the roof to 20 degrees. The maximum rainfall intensity shown represents the 100-year average recurrence interval of five-minute rainfall cycles. If there is roof infiltration, the total length of the roof will usually be greater than the distance from the ridge to the ridge where the infiltration impedes flow. Get in touch if you need further advice.
CGI sheets should be laid in normal weather and sit carefully on the front sheet of the roof with a lateral rotation of 1.5 corrugations, as shown in the laying method below. They should be adjusted within the recommended support interval. Do not “stretch” the width of the sheet when installing, as this will allow wind and rain to enter.
Recommended to maintain a weatherproof seal and protect the siding, especially when going on the roof. This is best done with 8 x 12mm self-drilling seam screws or 3.2mm blind rivets (rivets must be sealed to prevent water ingress). It is recommended that the lateral joints be reinforced at mid-span when the spans are greater than 900 mm for roofs and 1200 mm for walls.
In Style Patios And Decks
On the roof, at the end of the plate, the valleys of each wave must be lowered to the roof and to the gutter using the up/down tool.
* When it is attached to boards with a thickness of 0.55 mm; Crest Fix with M6 x 50mm TS self-tapping screws with neoprene washers. The specified interval will still apply.
If used according to specifications, CGI will have a long and useful life. While the useful life of roofing materials in urban and rural areas exceeds 30 years, in coastal and industrial environments it can be reduced to a few years.
Zinc/Al and pre-painted steel should not be used in aggressive areas such as near swimming pools and spas. It is important that dirt, soil, compost, sand or other materials that retain moisture are not placed against the steel sheet. Concrete should not be poured against zinc/alloy. Please check this area before using.
Stratco Edge Gutter Colorbond
The best way to reduce corrosion is to keep incompatible metals separate. Zinc/Al and pre-painted steel cannot be used with lead, copper and Monel. Galvanized steel and pure zinc materials can be used with zinc/aluminum, but you must avoid water flow from the zinc/aluminum to the galvanized materials. Fasteners such as screws and self-tapping screws must be compatible with the material to which they are fastened.
For safety, wear gloves when handling CGI. Make sure your hands or gloves are clean, especially when handling zinc/alloy which may be stained. Use a colored pencil to mark the steel, as lead or black pencils contain graphite, which causes rust. CGI is best cut using lead holes, but larger cuts may require the use of a power saw with a steel cutting blade or electric nibblers. Avoid using abrasive discs as they can damage the painted edges and finish. Trim the sheet to the ground as much as possible and gently remove any bits of surf and metal during installation. Remove the cuttings carefully.
Blanket insulation is recommended on home roofs to control temperature, condensation and sound. CGI can be used with an insulating blanket up to 55 mm thick. Greater thickness requires longer connectors and more care during installation.
When choosing a silicone sealant, make sure it is suitable for roof and gut use and is a neutral, neutral, neutral type. Ammonia, vinegar or lemon juice are not suitable at all.
Walling Or Cladding
The effectiveness of CGI over time depends on its proper implementation and maintenance. Maintenance should be done as necessary to remove any dirt, salts and contaminants. Where CGI is used in highly corrosive environments, cleaning should be done more frequently. It is important that the screws are the same as the CGI coating you specified.
CGI packages should always be stored in a dry place and above ground. If the sheets get wet, they should be cleaned separately and left in an open area to dry.
For detailed information on the proper use and maintenance of this product, refer to the Selection, Use and Maintenance brochure. About this product Maxirib has a slim and attractive profile which is ideal.